Static accuracy of resistive bend sensors - ENSTA Bretagne - École nationale supérieure de techniques avancées Bretagne Accéder directement au contenu
Communication Dans Un Congrès Année : 2020

Static accuracy of resistive bend sensors

Résumé

Sensing of finger joint rotation can be difficult due to the hand's many degrees-of-freedom within a small space. Resistive bend sensors offer a potentially attractive option for making these measurements due to their low profile, small mass, and low cost. Further characterization of these bend sensors is needed, however, to ensure that readings are accurate. Specifically the static accuracy when bending and straightening the sensor has not been investigated. In this study, two-inch resistive sensors were bent from 0° to 90° and back to 0° while measuring the voltage output. Five calibration models were fitted to the measured data and used to determine the sensor's accuracy. When used with coated sensors, both the cubic and pchip models demonstrated non-monotonic behavior at low bend angles. Using uncoated sensors, the pchip calibration function and raw data resulted in a median error of 1.7° (SD 1.7°, range 12.1°).

Dates et versions

hal-02956387 , version 1 (02-10-2020)

Identifiants

Citer

R Hollingshead, Louisa Henry-Etesse, Émilien Tankéré, D Kamper, T Tan. Static accuracy of resistive bend sensors. 2020 42nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) in conjunction with the 43rd Annual Conference of the Canadian Medical and Biological Engineering Society, Jul 2020, Montreal, Canada. pp.4672-4675, ⟨10.1109/EMBC44109.2020.9175166⟩. ⟨hal-02956387⟩

Collections

ENSTA-BRETAGNE
46 Consultations
4 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More