Accéder directement au contenu Accéder directement à la navigation
Article dans une revue

High contrast and resolution 3-D ultrasonography with a clinical linear transducer array scanned in a rotate-translate geometry

Théotim Lucas 1 Isabelle Quidu 2 S. Lori Bridal 1 Jerome Gateau 1
2 Lab-STICC_ENSTAB_CID_PRASYS
Lab-STICC - Laboratoire des sciences et techniques de l'information, de la communication et de la connaissance
Abstract : We propose a novel solution for volumetric ultrasound imaging using single-side access 3-D synthetic-aperture scanning of a clinical linear array. This solution is based on an advanced scanning geometry and a software-based ultrasound platform. The rotate-translate scanning scheme increases the elevation angular aperture by pivoting the array [-45° to 45°] around its array axis (axis along the row of its elements) and then, scans the imaged object for each pivoted angle by translating the array perpendicularly to the rotation axis. A theoretical basis is presented so that the angular and translational scan sampling periods can be best adjusted for any linear transducer array. We experimentally implemented scanning with a 5-MHz array. In vitro characterization was performed with phantoms designed to test resolution and contrast. Spatial resolution assessed based on the full-width half-maximum of images from isolated microspheres was increased by a factor 3 along the translational direction from a simple translation scan of the array. Moreover, the resolution is uniform over a cross-sectional area of 4.5 cm 2. Angular sampling periods were optimized and tapered to decrease the scan duration while maintaining image contrast (contrast at the center of a 5 mm cyst on the order of-26 dB for 4° angular period and a scan duration of 10 s for a 9cm 3 volume). We demonstrate that superior 3-D US imaging can be obtained with a clinical array using our scanning strategy. This technique offers a promising and flexible alternative to development of costly matrix arrays toward the development of sensitive volumetric ultrasonography.
Liste complète des métadonnées

https://hal.archives-ouvertes.fr/hal-03011745
Contributeur : Jérôme Gateau <>
Soumis le : lundi 25 janvier 2021 - 11:35:38
Dernière modification le : jeudi 28 janvier 2021 - 08:15:10

Identifiants

Citation

Théotim Lucas, Isabelle Quidu, S. Lori Bridal, Jerome Gateau. High contrast and resolution 3-D ultrasonography with a clinical linear transducer array scanned in a rotate-translate geometry. Applied Sciences, MDPI, 2021, 11 (2), pp.493. ⟨10.3390/app11020493⟩. ⟨hal-03011745v2⟩

Partager

Métriques

Consultations de la notice

87

Téléchargements de fichiers

71